Access Virus Rack – Restarts Due To Bad Capacitor

This Access Virus Rack was continuously restarting when power was connected. This is apparently a common issue with the Access Virus and is due to a capacitor in the power supply going bad. In this video I replace said capacitor.

I didn’t have to do any real troubleshooting here as there were various references to the problem online. Here is one example:

https://joeyfehrenbach.tumblr.com/post/76338854745/access-virus-b-the-synth-repair-adventure

The brown 100uF 25V capacitor is the one that goes bad
The brown 100uF 25V cap has been replaced
Entire board
Access Virus Rack